Fluke - True RMS Clamp-Meter - 2,000A AC/DC - Conductors to 58mm
Product Code: Fluke-353
Brand: Fluke
Digital clamp-meter measures AC and DC to 2,000A and frequency to 1kHz.
True RMS sensing meter provides accurate readings when measuring linear or non-linear loads, regardless of waveform.
Clamp with 58mm (2.3 inches) jaw opening fits around large or multiple conductors to measure current without touching or interrupting the circuit.
Inrush current function analyzes the surge current at the startup of motors and other inductive loads to provide accurate, stable measurements.
Meets IEC safety standard 61010-2-032, and is rated for CAT IV installations to 600V and CAT III installations to 1,000V.
Versatile and rugged tool for applications with high currents.
Confidently take reliable readings with the True RMS, Fluke 353 digital clamp meter: the tools of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.
Reliably handle a wide range of high-current applications with 2000 A AC + DC true-rms, 1400 A ac, and 2000 A DC.
The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors.
In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability.
Accurately measure frequency up to 1 kHz for optimum troubleshooting.
Quickly analyze readings using the MIN, MAX, and AVG functions.
Use the display hold feature to capture readings even when the display cannot be viewed.
Use the low-pass filter to smooth out noisy loads and stabilize readings.
Included: Fluke 353 2000 A Clamp Meter, C43 Soft Carrying Case, 6 AA batteries (Installed).
Maximum AC (alternating current) input2,000A(1,400A RMS)Maximum frequency detected1kHzInstallation rating CAT IV, 600V; CAT III, 1,000VStandards metIEC safety standard 61010-1; CE marking; CSA; Australia N10140Power supply(6) 1.5V AA batteriesWeight0.814kg/1.8lb.
Dimensions (H x W x D)300 x 98 x 52mm/12 x 3.75 x 2 inches, H is height, the vertical distance from lowest to highest point; W is width, the horizontal distance from left to right; D is depth, the horizontal distance from front to back.
Clamp-meters, also called clamp-on meters, have two jaws that fit around a conductor to measure electrical current without cutting through wires, or touching or interrupting the electrical circuit. Available in handheld or benchtop models, clamp-meters diagnose problems in electrical equipment, wiring, and power supplies.
All clamp-meters test for current. Some come with test leads and inputs for measuring voltage, capacitance, and resistance. They display information either in analog or digital form. Factors that influence meter choice include the electrical properties to be measured, the anticipated range of results, and the desired level of protection against transient voltage.
Safety ratings are based on International Electrotechnical Commission (IEC) standards for low-voltage test equipment. IEC 61010 delineates four overvoltage installation categories. In general, a meter with a category IV rating will provide more protection against transient voltages than a meter with a lower category rating. Fluke Corporation manufactures electrical testing tools and software for industrial and commercial applications. The company, founded in 1948, is headquartered in Everett, WA.
What's in the Box?
- Fluke 353 digital clamp-meter
- (6) AA batteries
- Soft carrying case
- User manual
| 355 True-RMS Clamp Meter |
AC Current Range | 0 to 1400 A |
DC Current Range | 0 to 2000 A |
AC/DC Voltage Range | 0 to 1000 V |
Resistance Range | 0 to 400 kΩ |
Jaw Opening | 58mm |
Max. Wire Size | 400 mm² |
Frequency Measurement Range | 5 to 1000 Hz |
Fluke Connect |
|
Safety Rating | CAT III 600 V |
| 355 True-RMS Clamp Meter | 353 True-RMS Clamp Meter | 365 True-RMS Clamp Meter | 381 True-RMS Clamp Meter |
AC Current Range | 0 to 1400 A | 0 to 1400 A | 0 to 200 A | 0 to 999.9 A |
DC Current Range | 0 to 2000 A | 0 to 2000 A | 0 to 200 A | 0 to 999.9 A |
AC/DC Voltage Range | 0 to 1000 V |
| 0 to 600 V | 0 to 1000 V |
Resistance Range | 0 to 400 kΩ |
| 0 to 6000 Ω | 0 to 60 kΩ |
Jaw Opening | 58mm | 58mm | 18mm | 34mm |
Max. Wire Size | 400 mm² | 400 mm² | 17mm | 400 mm² |
Frequency Measurement Range | 5 to 1000 Hz | 5 to 1000 Hz |
| 500 Hz |
Fluke Connect |
| ✓ | ✓ | ✓ |
Safety Rating | CAT III 600 V | CAT III 1000 V, CAT IV 600 V | CAT III 1000 V, CAT IV 600 V | CAT III 1000 V, CAT IV 600 V |