Fluke - 28-II Ex Intrinsically Safe True RMS Digital Multimeter

Fluke-28-IIEx
AED6,65477
Excl. VAT
1 Set (AED6,654.77 per Set)
In stock
Price in points: 6655 points
Haris Al Afaq
+971525361308

Product Code: Fluke-28-IIEx

Brand: Fluke

A completely sealed, IP67 rated case

Withstands drops up to 10 ft or 3 m (with holster)

Dustproof per IEC 60529 IP6x

Waterproof per IEC 60529 IPx7

CAT III 1000 V, CAT IV 600 V

Reversible holster for added protection of the display when not in use.

Now there's an intrinsically safe digital multimeter (DMM) you can use in a wide range of hazardous settings. Whether you work in petroleum, chemical, or pharmaceutical environments, the 28 II Ex gives high-end test and troubleshooting power you need is packed into the most rugged intrinsically safe (IS) DMM Fluke has ever built: drop-proof, waterproof, dust-proof (IP67). The 28 II Ex meets the following certifications:

IECEx (International)

Ex ia IIC T4 Gb

Ex ia I Ma

IECEx

ATEX (Europe)

II 2G Ex ia IIC T4 Gb

I M1 Ex ia I Ma

ATEX

NEC / CEC (North America)

Class I, Division 1, Groups A, B, C, D T4

Class I, Zone 1, AEx ia IIC T4

Ex ia IIC T4

NEC / CEC

PCEC (China)

Ex ia IIC T4 Gb

PCEC

Simtars (Australia)

Ex ia I Ma

Simtars

IEx (Brazil)

Ex ia IIC T4 Gb

IEx

EAC (Russia)

1Ex ia IIC T4 Gb X

PO Ex ia I Ma X

IP6X

EAC

 

All the measurement functions of our most popular industrial DMMs. One tool equips you with all the testing and troubleshooting power you need wherever you go––inside or outside ATEX zones 1 or 2,. No need to carry different meters for different areas, or worry about crossing through an Ex-required zone with a non-Ex rated instrument.

4-1/2-digit mode for precise measurements (20 000 counts).

True-rms ac voltage and current for accurate measurement on nonlinear signals.

Measures up to 1000 V and 10A AC and DC (note that Ex zones require reduced measurements).

Low pass filter ensures accurate voltage and frequency measurements on variable speed motor drives (VSDs).

Frequency to 200 kHz and % duty cycle to help you diagnose VSDs and switching power supplies.

Resistance, continuity and diode test.

10 000 μF capacitance range for components and motor caps.

Conductance measurements for high resistance or leakage tests.

Min/Max-Average and Peak capture to record transients and variations automatically.

Relative mode to remove test lead interference on resistance measurements.

Auto and manual ranging for maximum flexibility.

Input Alert protects you by chirping and flashing “Lead when leads are plugged into the wrong inputs.

Easy to use

Important extras keep you productive all day long in less-than-optimal conditions.

Backlit keypad buttons provide extra visibility in poorly lit areas, even when you’re wearing full PPE.

Large display digits and 2-level bright white backlight also increases visibility.

Long battery life – 400 hours typical without backlight (Alkaline).

Optional magnetic hanger for easy setup and viewing while freeing your hands for other tasks.

Easy to service in the field.

Access to the separate battery compartment makes it easy to change batteries or fuses without jeopardizing instrument calibration.

 

What's in the box:

  • Fluke 28 II Ex Intrinsically Safe Digital Multimeter
  • Ex-holster
  • (1 pair) Alligator clips
  • (1 pair) Test leads
  • Installed batteries

 

Accuracy Specifications

Accuracy specifications are shown as ±(% of reading + number of digits)

DC voltage

Range

0.1 mV to 1000 V

Accuracy

±(0.05% + 1)

AC voltage

Range

0.1 mV to 1000 V

Accuracy

±(0.7% + 4)

DC current

Range

0.1 μA to 10 A

Accuracy

±(0.2% + 4)

AC current

Range

0.1 μA to 10 A

Accuracy

±(1% + 2)

Resistance

Range

0.1 Ω to 50 MΩ

Accuracy

±(0.2% + 1)

Conductance

Range

60.00 nS

Accuracy

±(1.0% + 10)

Diode test

Range

2.0 V

Accuracy

±(2.0% + 1)

Duty cycle

Range

0.0% to 99.9>#/span###

Accuracy

Within ±(0.2% per kHz + 0.1%) for rise times <1 µs

Capacitance

Range

10 nF to 9999 μF

Accuracy

±(1% + 2)

Frequency

Range

0.5 Hz to 199.99 kHz

Accuracy

±(0.005% + 1)

Temperature

Range

-200°C to +1090°C (-328°F to +1994°F)

Accuracy

±(1% + 10)°C [±(1% + 10)°F]

Display counts

6000 counts/19,999 counts in high-resolution mode

Peak capture

Record transients up to 250 us

Min/Max/Avg recording

Display signals up to approximately 100 ms

Accuracy specifications are shown as ±(% of reading + number of digits)

Safety Certifications

ATEX

{Ex} II 2G Ex ia IIC T4 Gb

{Ex} I M1 Ex ia I Ma

NEC-500

Class I, Div 1, Groups A-D, 130°C

IECEx

Ex ia IIC T4 Gb

Ex ia I Ma

GOST R Ex

1Ex ia IIC T4 Gb X

PO Ex ia I Ma X

IP6X

General Specifications

Power

Three AAA batteries

Battery life: 400 hours

Display

LCD, with backlight

External protection

Rubber holster

Warranty

Three years

Size with holster (H x W x L)

6.4 x 10.0 x 19.8 cm (2.5 x 3.9 x 7.8 in)

Weight with holster

700 g (1.54 lb)

Brand
Fluke
Find similar

TDS-28IIEX (28IIEX.pdf, 181 Kb) [Download]

USER MANUAL (28iiEX__u-menual.pdf, 1,922 Kb) [Download]

Calibration Manual (28iiex__Calib.pdf, 690 Kb) [Download]

Possibly you may be interested
  • Most Popular
  • Bestsellers
  • Recently Viewed
 
 
 
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase