Fluke - True RMS 2000 A Clamp Meter - Versatile And Rugged

Fluke-355
AED3,75142
Excl. VAT
In stock
Price in points: 3752 points
Haris Al Afaq
+971525361308

Product Code: Fluke-355

Brand: Fluke

Reliably handle a wide range of high-current applications with 2000 A AC + DC True RMS, 1400 A AC, and 2000 A DC.

The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors.

CAT IV 600 V, CAT III 1000 V rating for added user protection.

In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability.

 

Versatile and rugged clamp meter for high currents

Confidently take reliable readings with the True RMS Fluke 355 digital clamp meter, the tool of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.

Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.

 

Easy to use all-in-one tool

High voltage measurement of 1000 V AC + DC True RMS, 600 V AC, and 1000 V DC allows the user to perform multiple tests with only one tool.

Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter.

Accurately measure frequency up to 1 kHz for optimum troubleshooting.

Quickly analyze readings using the MIN, MAX, and AVG functions.

A large backlit display allows for easy visibility in low-lit areas.

Use the display hold feature to capture readings even when the display cannot be viewed.

Use the low-pass filter to smooth out noisy loads and stabilize readings.

 

Electrical Specifications

Current measurement DC and AC 10 Hz to 100 Hz

Range

40 A / 400 A / 2000 A / 1400 AC rms

Resolution

10 mA / 100 mA / 1 A

Accuracy

A: 1.5% rdg + 15 digits A: 1.5% rdg + 5 digits

Trigger level for Inrush

0.50 A / 5.0 A / 5 A

Trigger level for Hz filter OFF

2.50 A / 2.5 A / 8 A

Trigger level for Hz filter ON

0.50 A / 2.5 A / 8 A

Crest Factor (50/60 Hz)

Range

40 A / 400 A / 2000 A / 1400 AC rms

Crest Factor1

2 @ 33 A, 2.4 @ 27 A 2 @ 330 A, 2.4 @ 270 A 2 @ 1000 A, 2.4 @ 833 A

Current measurement AC 100.1 Hz to 1 kHz

Range

40 A / 400 A / 2000 A; 1400 AC rms

Resolution

10 mA / 100 mA / 1 A

Accuracy

10 A: 3.5% rdg + 15 digits 10 A: 3.5% rdg + 5 digits

Trigger level for Inrush

0.50 A / 5.0 A / 5 A

Trigger level for Hz filter OFF

2.50 A / 2.5 A / 8 A

Trigger level for Hz filter ON

0.50 A / 2.5 A / 8 A

Voltage measurement DC and AC 10 Hz to 100 Hz (600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.)

Range

4 V / 40 V / 400 V / 600 V AC rms / 1000 VDC

Resolution

1 mV / 10 mV / 100 mV / 1 V

Accuracy

1% rdg + 10 digits 1% rdg + 5 digits

Trigger level for Hz filter OFF

0.25 V / 6 V

Trigger level for Hz filter ON

0.25 V / 6 V

Voltage measurement AC 100.1 Hz to 1 kHz (600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.)

Range

4 V / 40 V / 400 V / 600 V ac rms

Resolution

1 mV / 10 mV / 100 mV / 1 V

Accuracy

3% rdg + 10 digits 3% rdg + 5 digits

Trigger level for Hz filter OFF

0.050 V / 0.25 V / 6 V

Trigger level for Hz filter ON

0.050 V / 0.25 V / 6 V

Ohms measurement

Range

4 kΩ / 40 kΩ / 400 kΩ

Resolution

0.1 Ω / 1 Ω / 10 Ω / 100 Ω

Accuracy

1.5% + 5 digits

Continuity beeper

On at ≤ 30 Ω Off at ≥ 100 Ω

Frequency measurement

Measurement range

5.0 Hz to 1 kHz

Resolution

0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)

Accuracy – 5.0 Hz to 100 Hz

0.2% + 2 counts

Accuracy – 100.1 Hz to 1 kHz

0.5% + 5 counts

Trigger level

Refer to current and voltage tables

1. Add 2% to error spec for CF > 2

General Specifications

Batteries

Six 1.5 V AA NEDA 15 A or IEC LR6

Battery life (with typical usage, backlight off)

100 hours

Test leads

Rated to 1000 V

Weight

.814 kg (1.8 lb)

Jaw size

58 mm (2.28 in)

Dimensions (L x W x D)

300 x 98 x 52 mm (12 x 3.75 x 2 in)

Safety rating

IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III

Environmental Specifications

Operating temperature

32°F to +122°F (0°C to +50°C)

Storage temperature

-4°F to 140°F (-20°C to +60°C)

Operating humidity

0 to 95% (non-condensing)

Operating altitude

2000 m

Storage altitude

10,000 m

IP rating

42 (indoor use only)

Drop test requirements

1 m

EMI, RFI, EMC

FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3 V/m, performance criteria B, EN61325

Temperature coefficients

Current

0.1% of reading per °C outside 22°C to 24°C

Voltage

0.1% of reading per °C outside 22°C to 24°C

Brand
Fluke
Find similar

353,355 TDS.pdf (353,355_TDS.pdf, 462 Kb) [Download]

353_355_user menual (353_355_user_menual.pdf, 879 Kb) [Download]

353_355_Instrument Security Procedures (353_355_Instrument_Security_Procedures.pdf, 7 Kb) [Download]

Possibly you may be interested
  • Most Popular
  • Bestsellers
  • Recently Viewed
 
 
 
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase