Fluke - FC Leakage Current Clamp Meter

FLUKE-369-FC-UMS
AED3,19428
Excl. VAT
In stock
Price in points: 3195 points
Haris Al Afaq
+971525361308

Brand: Fluke

Measure leakage current to track small problems, avoid large problems.

The Fluke 360 Series of true-rms leakage current clamp meters help users detect, document, record and compare leakage current readings over time as a means of preventing unplanned downtime, and identifying intermittent GFCI and RCD trips, without taking equipment off line.

 

The Fluke 368 FC and 369 FC have large diameter jaws (40 mm for the 368 FC, 61 mm for the 369 FC) for work with larger conductors. The clamp’s jaw is fully shielded to accurately capture very small leakage signals, and to minimize external electromagnetic interference.

 

The 368 FC and 369 FC also offer wireless data connectivity via Fluke Connect. As part of Fluke Connect—the industry’s largest system of software and more than 40 wireless test tools the 368 FC and 369 FC allow you to track changes in leakage current over time, helping to identify potential problems before they turn into major failures.

 

Fluke Connect Compatible

(368 FC, 369 FC only)

Download the free Fluke Connect® app from iTunes or Google Play to enable graphs for trending.

Work light, Backlight

Forward-facing work light, plus backlit display for use in dark wiring cabinets.

Specialized Correct Measurements

Highest resolution of 1 μA, measure up to 60 A, true-rms for accurate measurements of complex signals.

 

Fluke-368-FC-UMS

True-rms measurements for accuracy when measuring complex, non-sinusoidal waveforms.

40 mm jaw opening.

Highest resolution of 1 μA, measure up to 60 A.

Selectable filter function removes unwanted noise.

Max/Min/Average readings and hold function.

Forward-facing LED work light for use in dark wiring cabinets.

Backlit display; auto backlight off and auto power off for extended battery life.

CAT III 600V safety rating.

Internal Memory Logging: up to 65,000 measurement points.

 

Fluke-369-FC-UMS

True-rms measurements for accuracy when measuring complex, non-sinusoidal waveforms.

61 mm jaw opening.

Highest resolution of 1 μA, measure up to 60 A.

Selectable filter function removes unwanted noise.

Max/Min/Average readings and hold function.

Forward-facing LED work light for use in dark wiring cabinets.

Backlit display; auto backlight off and auto power off for extended battery life.

CAT III 600V safety rating.

 

What's in the box:

  • Leakage Clamp Meter
  • Soft case
  • Two AA Batteries (Installed)
  • Quick Reference Guide

 

Electrical Specifications 368

Measurement function

Alternating current

AC ampere range

3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A

 

mA / A: manual selection 3 mA / 30 mA / 300 mA: automatic selection 3 A / 30 A / 60 A: automatic selection

Range / Resolution

3 mA¹ / 0.001 mA

30 mA / 0.01 mA

300 mA / 0.1 mA

3 A / 0.001 A

30 A / 0.01 A

60 A / 0.1 A

Accuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz)²

3 mA – 30 A 60 A

1% + 5 digits 2% + 5 digits

Frequency

40 Hz to 1 kHz

Crest Factor

3

After calibration accuracy is valid for one year. Accuracy is expressed as ± (% of reading + digits). Reference conditions 23 ±5 °C and a maximum relative humidity of 80%. ¹The minimum value is 10 μA rms. ²Outside of the TC / °C 18 °C to 28 °C, 0.02 + 1

Physical

Display (LCD)

Digital readout: 3300 count

Display refresh rate

4 times / sec

Maximum conductor diameter

40 mm

Dimensions

234 x 101 x 46 mm

Weight

500 g

Battery

2 AA, IEC LR6, NEDA 15A, alkaline

Battery life

Expected battery life, without using backlight and spotlight, is more than 150 hours

Automatic shut-down

Meter automatically shuts down after 15 minutes of inactivity

Safety and Environmental Specifications

General safety

IEC 61010-1: Pollution Degree 2

Measurement safety

IEC 61010-2-032: CAT III 600 V / CAT IV 300 V

Operating temperature

-10 °C to +50 °C

Storage temperature

-40 °C to +60 °C

Operating humidity

Non-condensing (<10 °C)

90% relative humidity (10 °C to 30 °C)

75% relative humidity (30 °C to 40 °C)

45% relative humidity (40 °C to 50 °C)

Protection class

IEC 60529: IP30 (jaw closed)

Operating altitude

2000 m

Storage altitude

12000 m

Current sensor action category

IEC 61557-13: Class 2, ≤30 A / m

 

 

Electrical Specifications 369

Measurement function

Alternating current

AC ampere range

3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A

Range selection

mA / A: manual selection 3 mA / 30 mA / 300 mA: automatic selection 3 A / 30 A / 60 A: automatic selection

Range / Resolution

3 mA¹ / 0.001 mA

30 mA / 0.01 mA

300 mA / 0.1 mA

3 A / 0.001 A

30 A / 0.01 A

60 A / 0.1 A

Accuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz)²

3 mA – 30 A 60 A

1% + 5 digits 2% + 5 digits

Frequency

40 Hz to 1 kHz

Crest Factor

3

After calibration accuracy is valid for one year. Accuracy is expressed as ± (% of reading + digits). Reference conditions 23 ±5 °C and a maximum relative humidity of 80%. ¹The minimum value is 10 μA rms. ²Outside of the TC / °C 18 °C to 28 °C, 0.02 + 1

Physical

Display (LCD)

Digital readout: 3300 count

Display refresh rate

4 times / sec

Maximum conductor diameter

61 mm

Dimensions

257 x 116 x 46 mm

Weight

600 g

Battery

2 AA, IEC LR6, NEDA 15A, alkaline

Battery life

Expected battery life, without using backlight and spotlight, is more than 150 hours

Automatic shut-down

Meter automatically shuts down after 15 minutes of inactivity

Safety and Environmental Specifications

General safety

IEC 61010-1: Pollution Degree 2

Measurement safety

IEC 61010-2-032: CAT III 600 V / CAT IV 300 V

Operating temperature

-10 °C to +50 °C

Storage temperature

-40 °C to +60 °C

Operating humidity

Non-condensing (<10 °C)

90% relative humidity (10 °C to 30 °C)

75% relative humidity (30 °C to 40 °C)

45% relative humidity (40 °C to 50 °C)

Protection class

IEC 60529: IP30 (jaw closed)

Operating altitude

2000 m

Storage altitude

12000 m

Current sensor action category

IEC 61557-13: Class 1, ≤100 A / m

 

Brand
Fluke
Find similar

368-69 user Manual (368-69_user_Manual.pdf, 3,779 Kb) [Download]

368 369 fc Quick ref (368fc_Quick_ref.pdf, 2,537 Kb) [Download]

368-369 supliments (368-369_supliments.pdf, 11 Kb) [Download]

368-369 Radio Frequency Data (368-369Radio_Frequency_Data.pdf, 501 Kb) [Download]

368-69 technical data (368-69_technical_data.pdf, 1,184 Kb) [Download]

Possibly you may be interested
  • Most Popular
  • Bestsellers
  • Recently Viewed
 
 
 
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase